Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Clinical and Esthetic Evaluation Following Immediate Implant Placement and Restoration with Platform- Switched Morse Taper Implants in the Esthetic Zone: A Cross-Sectional Study
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 42 , Issue 5
September/October 2022

Pages 665–673


Clinical and Esthetic Evaluation Following Immediate Implant Placement and Restoration with Platform- Switched Morse Taper Implants in the Esthetic Zone: A Cross-Sectional Study

Karina Obreja, DDS/Amira Begić, DDS/Georgia Trimpou, DMD/Maria Elisa Galarraga-Vinueza, MSc, PhD, DMD/Ümniye Balaban, PhD/Frank Schwarz, DDS/Puria Parvini, MSc, DDS


PMID: 36044699
DOI: 10.11607/prd.5942

Immediate implant placement with immediate restoration in the esthetic zone is a standardized protocol that aims to satisfy the patient with an immediate, esthetic rehabilitation. This study evaluated clinical and esthetic outcomes following immediate implant placement and provisionalization over a medium- to long-term period. A total of 57 implants in 44 patients were included in the present cross-sectional study, with a follow-up period of 3.97 ± 2.03 years. Surgical and prosthetic treatments were performed according to a standardized protocol. Clinical outcomes (modified Plaque Index, bleeding on probing, probing depth [PD], keratinized mucosa, mucosal recession [MR], and pink esthetic score [PES]) were evaluated during follow-up. Peri-implant tissue health was assessed based on the established case definitions. The mean PES value at the final control examination (mean PES follow-up time: 3.79 ± 1.85 years) was 12.06, the mean PD was 2.52 ± 0.88 mm, and mean MR was 0.03 ± 0.13 mm. No suppuration, pain, or implant or prosthetic failures were reported. The prevalence rates of mucositis and peri-implantitis were 45.5% and 0%, respectively. Immediate implant placement and restoration was associated with peri-implant tissue stability and esthetics over medium- and long-term follow-up periods.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help